Abstract
Introduction: tibial eminence fractures are uncommon injuries but are frequently associated to concomitant injuries. MRI is considered the Gold Standard; it allows a detailed evaluation of any soft tissue involvement with the injury.
Case presentation: an unusual presentation case is reported: a displaced tibial spine fracture and a bucket handle medial meniscus injury. Arthroscopic reduction and fixation were performed, using two bioabsorbable pins for the tibial spine fixation; and three all-inside and two vertical outside-in sutures were needed for the medial meniscus repair.
Conclusion: the patient presented excellent clinical outcomes, without presenting inherent complications due to primary injury nor realized treatment, achieving sport activity levels prior to injury.
Todo el material publicado en el Revista Artroscopia está cedido a la Asociación Argentina de Artroscopia (AAA). De conformidad con la Ley de Derecho de Autor (Ley 11.723), al autor correspondiente de cada manuscrito se le pedirá que complete un formulario de cesión de derechos de autor sobre la aceptación del manuscrito. Al enviar un artículo el autor(es) debe hacer una declaración completa al editor sobre todas las presentaciones e informes previos que pudieran considerarse como publicación previa o duplicada del mismo trabajo o muy similares. Copias de dicho material debe ser incluido en el documento presentado para ayudar al editor a decidir cómo tratar el asunto.